EMI/RFI Analyzers & Antennas > EMC Receivers > 9230-1 9229-1 Radiating Loop & Loop Sensor by Solar

9230-1 9229-1 Radiating Loop & Loop Sensor

 Request a Quote

Product Description & Specs

Test Method RS101 of MIL-STD-461D requires radiated magnetic fields over the frequency range 30 Hz to 100 KHz to determine the susceptibility or immunity of the equipment under test (EUT). Two loop antennas are required for compliance with the requirements.The radiating loop is 12 cm in diameter and the sensing loop (used for calibration) is 4 cm in diameter. The Type 9230-1 Radiating Loop has been designed so that the Type 9229-1 Loop Sensor can be attached at the required 5 cm distance.

9230 1 9229 1

E-mail or call us at 800-582-8378 for more information.