Impedance Measurement (R,L,C,Q,D) > RLC Bridges / Meters > 1730 Precision LCR Meter 50Hz-100KHz by Quadtech
1730 Precision LCR Meter 50Hz-100KHz
| |  |  |
Product Description & Specs
The QuadTech 1730 can measure and display two of 14 impedance parameters simultaneously with a basic accuracy of 0.1%. Test results can also be shown as Deviation or %Deviation from nominal value. 10 Test Frequencies: User selectable: 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz and 100kHz. LCD Display: Large, high resolution graphic display for clear, concise results and user friendly menu interface for easy programming. Setup Store/Recall: Store/Recall up to 50 test setups from instrument memory. Lockout front panel to ensure procedures are run the same way every time. Programmable Source Impedance: Program tester impedance to 100 ohm, 100/25 ohm, 25 ohm or 10 ohm constant current when comparing results with measurements made on other testers. Measurement results can vary significantly based solely on the source impedance of the tester being used. Voltage/Current Monitoring: Use the test signal monitoring function to display the actual voltage level across and current through the DUT. DC Bias: External and internal DC Bias voltage from 0-5V, permits capacitors to be tested under real DC bias conditions. Open/Short Zeroing: Reduce the effects of error sources (stray admittance/residual impedance) between the DUT and the calibrated connection to the measuring instrument.Fast Testing: Select from one of three measurement speeds: slow, medium or fast for varying degrees of accuracy and speed up to 62 measurements/second. Interfaces Standard: The 1730 unit includes IEEE-488 and Handler interfaces for adaption into production environments or remote control applications.
Features
Measures 14 Impedance Parameters (2 simultaneously)
0.1% Basic Measurement Accuracy
10 Test Frequencies from 50Hz to 100kHz
AC Test Voltage Programmable from 10mV to 1V
Fast Measurement Speeds up to 62/Second
Automatic Open/Short Zeroing Eliminates Connection Errors
LCD Display for Menu Programming and Test Results
Hi/Lo Comparator Limits and 8 Sorting Bins for Pass Fail Testing
IEEE-488 and PLC Interfaces Standard
Results Displayed as Deviation or %Deviation from a Nominal Value
Storage and Recall of 50 Test Setups
Monitor Voltage and Current to the Device Under Test
Keypad Lockout Prevents Changes to the Test Setup
Programmable Average and Delay Times
Capable of Applying a DC Bias Voltage or Current to the Device
Automatic Correction for Different Test Lead Lengths E-mail or call us at 800-582-8378 for more information. |